Merge branch 'main' of http://intechrnd.iptime.org:3000/SJ84/INT63DC_6CH
# Conflicts: # INT63DC_6CH.suo # INT63DC_6CH/bin/Release/INT63DC_6CH.exe # INT63DC_6CH/bin/Release/INT63DC_6CH.pdbmain
commit
f332fa6bdd
|
@ -1 +1,3 @@
|
|||
INT63DC_6CH/obj/
|
||||
INT63DC_6CH/bin/Release/INT63DC_6CH.exe
|
||||
INT63DC_6CH/bin/Release/INT63DC_6CH.pdb
|
||||
|
|
|
@ -1476,12 +1476,12 @@ namespace INT63DC_6CH
|
|||
this.Number = 1;
|
||||
this.Name = "ProductName 1";
|
||||
this.LotNo = "Lot 1";
|
||||
this.UnderRange = "1000";
|
||||
this.PassRange = "2000";
|
||||
this.OverRange = "3000";
|
||||
this.UnderRange = "10000";
|
||||
this.PassRange = "20000";
|
||||
this.OverRange = "30000";
|
||||
this.TareRange = "0";
|
||||
this.UnderRange = "0";
|
||||
this.OverRange = "99999";
|
||||
this.UnderRangeLimit = "0";
|
||||
this.OverRangeLimit = "999999";
|
||||
}
|
||||
|
||||
private void ProgressBarLevelRescale()
|
||||
|
@ -2206,7 +2206,6 @@ namespace INT63DC_6CH
|
|||
private bool m_IsServoAlarmTorque;
|
||||
private bool m_IsServoOff;
|
||||
private bool m_IsInverterAlarm;
|
||||
private bool m_IsAlignError;
|
||||
private bool m_IsPinchPoint;
|
||||
|
||||
private bool m_IsBuzzerStatus;
|
||||
|
@ -2260,11 +2259,6 @@ namespace INT63DC_6CH
|
|||
get { return this.m_IsInverterAlarm; }
|
||||
set { this.m_IsInverterAlarm = value; }
|
||||
}
|
||||
public bool IsAlignError
|
||||
{
|
||||
get { return this.m_IsAlignError; }
|
||||
set { this.m_IsAlignError = value; }
|
||||
}
|
||||
public bool IsPinchPoint
|
||||
{
|
||||
get { return this.m_IsPinchPoint; }
|
||||
|
@ -2289,7 +2283,6 @@ namespace INT63DC_6CH
|
|||
this.IsServoAlarmTorque = false;
|
||||
this.IsServoOff = false;
|
||||
this.IsInverterAlarm = false;
|
||||
this.IsAlignError = false;
|
||||
this.IsPinchPoint = false;
|
||||
|
||||
this.IsBuzzerStatus = false;
|
||||
|
@ -2318,57 +2311,57 @@ namespace INT63DC_6CH
|
|||
this.IsBuzzerStatus = false;
|
||||
}
|
||||
else
|
||||
this.IsPinchPoint = true;
|
||||
this.IsPinchPoint = true;
|
||||
#endregion
|
||||
#region 알람 15-봉 정렬 에러(정렬기)
|
||||
#region 알람 15-
|
||||
if (sValue4[1] == '0')
|
||||
this.IsAlignError = false;
|
||||
{ }
|
||||
else
|
||||
this.IsAlignError = true;
|
||||
{ }
|
||||
#endregion
|
||||
#region 알람 14-
|
||||
if (sValue4[2] == '0')
|
||||
{ }
|
||||
else
|
||||
{ }
|
||||
{ }
|
||||
#endregion
|
||||
#region 알람 13-
|
||||
if (sValue4[3] == '0')
|
||||
{ }
|
||||
else
|
||||
{ }
|
||||
{ }
|
||||
#endregion
|
||||
|
||||
#region 알람 12-서보알람토크
|
||||
if (sValue3[0] == '0')
|
||||
this.IsServoAlarmTorque = false;
|
||||
else
|
||||
this.IsServoAlarmTorque = true;
|
||||
this.IsServoAlarmTorque = true;
|
||||
#endregion
|
||||
#region 알람 11-
|
||||
if (sValue3[1] == '0')
|
||||
{ }
|
||||
else
|
||||
{ }
|
||||
{ }
|
||||
#endregion
|
||||
#region 알람 10-서보알람
|
||||
if (sValue3[2] == '0')
|
||||
this.IsServoAlarm = false;
|
||||
else
|
||||
this.IsServoAlarm = true;
|
||||
this.IsServoAlarm = true;
|
||||
#endregion
|
||||
#region 알람 9-인버터알람
|
||||
if (sValue3[3] == '0')
|
||||
this.IsInverterAlarm = false;
|
||||
else
|
||||
this.IsInverterAlarm = true;
|
||||
this.IsInverterAlarm = true;
|
||||
#endregion
|
||||
|
||||
#region 알람 8-비상정지
|
||||
if (sValue2[0] == '0')
|
||||
this.IsEmergencyStop = false;
|
||||
else
|
||||
this.IsEmergencyStop = true;
|
||||
this.IsEmergencyStop = true;
|
||||
#endregion
|
||||
#region 알람 7-
|
||||
if (sValue2[1] == '0')
|
||||
|
@ -2399,19 +2392,19 @@ namespace INT63DC_6CH
|
|||
if (sValue1[1] == '0')
|
||||
this.IsPressureError = false;
|
||||
else
|
||||
this.IsPressureError = true;
|
||||
this.IsPressureError = true;
|
||||
#endregion
|
||||
#region 알람 2-셀 에러
|
||||
if (sValue1[2] == '0')
|
||||
this.IsLoadcellError = false;
|
||||
else
|
||||
this.IsLoadcellError = true;
|
||||
this.IsLoadcellError = true;
|
||||
#endregion
|
||||
#region 알람 1-입력센서 에러
|
||||
if (sValue1[3] == '0')
|
||||
this.IsEntrySensorError = false;
|
||||
else
|
||||
this.IsEntrySensorError = true;
|
||||
this.IsEntrySensorError = true;
|
||||
#endregion
|
||||
}
|
||||
#endregion
|
||||
|
|
|
@ -1677,7 +1677,7 @@ namespace INT63DC_6CH.Forms
|
|||
|
||||
if (alarm.IsEntrySensorError == true || alarm.IsLoadcellError == true || alarm.IsPressureError == true ||
|
||||
alarm.IsEmergencyStop == true || alarm.IsInverterAlarm == true || alarm.IsServoAlarm == true || alarm.IsServoAlarmTorque == true ||
|
||||
alarm.IsAlignError == true || alarm.IsPinchPoint == true)
|
||||
alarm.IsPinchPoint == true)
|
||||
{
|
||||
this.pictureBoxAlarm.Visible = true;
|
||||
}
|
||||
|
@ -1719,11 +1719,6 @@ namespace INT63DC_6CH.Forms
|
|||
this.MainDisplayAlarmList.listBoxMessage.AddItem("Servo Torque Alarm");
|
||||
isAlarmMessageView = true;
|
||||
}
|
||||
if (alarm.IsAlignError == true)
|
||||
{
|
||||
this.MainDisplayAlarmList.listBoxMessage.AddItem("Product discharge error");
|
||||
isAlarmMessageView = true;
|
||||
}
|
||||
if (alarm.IsInverterAlarm == true)
|
||||
this.UpdateAlarmMessageDisplay();
|
||||
|
||||
|
@ -1789,8 +1784,6 @@ namespace INT63DC_6CH.Forms
|
|||
this.smartListBox1.AddItem("Servo Torque Alarm");
|
||||
if (alarm.IsEntrySensorError == true)
|
||||
this.smartListBox1.AddItem("Entry Sensor Error");
|
||||
if (alarm.IsAlignError == true)
|
||||
this.smartListBox1.AddItem("Product discharge error");
|
||||
|
||||
// bypass 설정 체크
|
||||
bool isBypass = false;
|
||||
|
|
Binary file not shown.
Binary file not shown.
Loading…
Reference in New Issue