parent
b3d6e14374
commit
9f3b2fad32
|
@ -25,8 +25,8 @@ namespace ITC81DB_2H.Forms
|
||||||
public partial class FormMain : Form
|
public partial class FormMain : Form
|
||||||
{
|
{
|
||||||
#region Field
|
#region Field
|
||||||
public static string DisplayVersion = "3.3.2";
|
public static string DisplayVersion = "3.3.3";
|
||||||
public static string ReleaseDate = "2024.03.06";
|
public static string ReleaseDate = "2024.08.06";
|
||||||
|
|
||||||
private SmartSplash SmartSplashProgramLoad;
|
private SmartSplash SmartSplashProgramLoad;
|
||||||
public bool IsCommunicationLogOpen;
|
public bool IsCommunicationLogOpen;
|
||||||
|
@ -7110,6 +7110,8 @@ namespace ITC81DB_2H.Forms
|
||||||
if (this.IsOPCModbusUsing == false)
|
if (this.IsOPCModbusUsing == false)
|
||||||
return;
|
return;
|
||||||
|
|
||||||
|
byte[] productName;
|
||||||
|
|
||||||
if (this.UpdateValue > 999999999)
|
if (this.UpdateValue > 999999999)
|
||||||
this.UpdateValue = 0;
|
this.UpdateValue = 0;
|
||||||
else
|
else
|
||||||
|
@ -7181,9 +7183,19 @@ namespace ITC81DB_2H.Forms
|
||||||
this.Current30000ModbusData.Speed = this.CurrentWeightData.ProductionSpeed;
|
this.Current30000ModbusData.Speed = this.CurrentWeightData.ProductionSpeed;
|
||||||
this.Current30000ModbusData.MetalDetectionCount = (UInt32)this.CurrentWeightData.MetalDetectionCount;
|
this.Current30000ModbusData.MetalDetectionCount = (UInt32)this.CurrentWeightData.MetalDetectionCount;
|
||||||
this.Current30000ModbusData.DoubleEntryCount = (UInt32)this.CurrentWeightData.DoubleEntryCount;
|
this.Current30000ModbusData.DoubleEntryCount = (UInt32)this.CurrentWeightData.DoubleEntryCount;
|
||||||
byte[] productName = new UTF8Encoding().GetBytes(this.CurrentProductItem.Name);
|
|
||||||
|
try
|
||||||
|
{
|
||||||
|
productName = new UTF8Encoding().GetBytes(this.CurrentProductItem.Name);
|
||||||
for (int i = 0; i < productName.Length; i++)
|
for (int i = 0; i < productName.Length; i++)
|
||||||
this.Current30000ModbusData.ProductName[i] = productName[i];
|
this.Current30000ModbusData.ProductName[i] = productName[i];
|
||||||
|
}
|
||||||
|
catch
|
||||||
|
{
|
||||||
|
productName = new UTF8Encoding().GetBytes(this.SystemConfig1.ProductNumber.ToString() + "_Name");
|
||||||
|
for (int i = 0; i < productName.Length; i++)
|
||||||
|
this.Current30000ModbusData.ProductName[i] = productName[i];
|
||||||
|
}
|
||||||
|
|
||||||
this.ChildFormMainDisplay.MainModbus.UpdateData(this.Current30000ModbusData);
|
this.ChildFormMainDisplay.MainModbus.UpdateData(this.Current30000ModbusData);
|
||||||
}
|
}
|
||||||
|
|
|
@ -13,6 +13,11 @@
|
||||||
기본형 컨베어 고정밀센서 계량기
|
기본형 컨베어 고정밀센서 계량기
|
||||||
*/
|
*/
|
||||||
|
|
||||||
|
@ Ver 3.3.3 by CJY
|
||||||
|
- 2024.08.07
|
||||||
|
- Ver 3.3.2 Modify
|
||||||
|
- Modbus 데이터 변환 시 품목명에 변환 불가능한 특수문자 있을 경우 '품번_Name'으로 전송하도록 수정
|
||||||
|
|
||||||
@ Ver 3.3.2 by CJY
|
@ Ver 3.3.2 by CJY
|
||||||
- 2024.02.22
|
- 2024.02.22
|
||||||
- Ver 3.3.1 Modify
|
- Ver 3.3.1 Modify
|
||||||
|
|
Binary file not shown.
Binary file not shown.
Loading…
Reference in New Issue